Aggregate of blood oxygen saturation module for Desfibrillator 3850B
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
- SpO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
- Pulse rate:
Range: 20 to 300 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

ACCESSORIES
SpO2 sensor, quantity 1.
SpO2 extension cable, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Recorder module for Desfibrillator 3850B
RECORDER
- Registration hotkey.
- High resolution thermal array printer.
-Resolution
Y axis: 8 points per mm.
X axis: 16 points per mm.
- Paper: width: 50 mm, maximum diameter: 45 mm.
-Printing width: 48 mm.
- Registration speed: 25 mm/s.
- Records the type of patient, the date, the time and in real time, 1 or 2 curves: electrocardiogram and percentage oxygen saturation or cascade electrocardiogram.
-A 50mm x 25m roll of thermal paper is delivered for the UC50 recorder


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of pacemaker module for Desfibrillator 3850B
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

TRANSCUTANEOUS PACEMAKER
- Pacemaker electrode output: Type CF.
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (adjustable in steps of 5 ppm).
- Current: 10 mA to 200 mA (adjustable in steps of 5 mA).
- Mode: Selectable, demand or asynchronous.
- Pulse width: 20 ms ± 5%.
- Frequency Accuracy: Within ±5% of displayed value.
-Pacemaker current accuracy: From 10mA to 45mA is ±5mA.
From 50 mA to 200mA is 10%
-Refractory period: 340 ms for frequencies less than or equal to 80 ppm, 240 ms for frequencies greater than 80 ppm.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pediatric pulse oximeter with Clamp and DB9M/G, Feas Electrónica 3178
Pediatric pulse oximeter with Clamp and DB9M/G, Feas Electrónica 3178

The reusable finger sensor is used in oximetry monitoring systems to non-invasively determine Oxygen saturation (SpO2), pulse rate, and pulse plethysmographic waves.

The reusable pediatric finger sensor is recommended for:
• Patients weighing more than 5Kg and less than 45Kg.
• Patients with limited activity.
• For sampling.

The reusable pediatric finger sensor is not recommended for long-term use. For long-term patient monitoring, use disposable single-patient or wrap-around type sensors.
It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 2.5 meters.
Protection against liquids: IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult pulse oximeter sensor with clamp and DB9M/G 3444, Feas Electrónica
Adult pulse oximeter sensor with clamp and DB9M/G 3444, Feas Electrónica

The reusable finger sensor Feas ELECTRONICA ref. 5043 is used to non-invasively determine oxygen saturation (SpO2), pulse rate, and pulse plethysmographic waves. It is indicated for:
• Patients who weigh more than 15Kg.
• Patients with limited activity.

The reusable finger sensor is not recommended for prolonged use, unless the integrity of the skin is checked frequently and the application site is changed accordingly. For long-term patient monitoring, use either single-patient disposable sensors or Velcro-strap sensors.
It has a length of 1 meter.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Neonatal oximeter sensor DB9M/G Feas Electrónica 3026
Neonatal oximeter sensor DB9M/G Feas Electronica 3026.

This sensor is used in oximetry monitoring systems to non-invasively determine Percent Oxygen Saturation (SpO2), pulse rate, and pulse plethysmographic waves.
Its use is indicated for patients of less than 3kg.

It has a length of 40 cm.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Reusable “Y” Sensor, Neonatal, Foot, Feas ELECTRÓNICA , 518B
The multifunctional and reusable Oximeter sensor is indicated for non-invasive monitoring by continuous sampling of arterial oxygen saturation and pulse rate of newborn patients (weighing less than 5 kg). It can be applied to the foot of the newborn patient. It can also be used in adult and pediatric patients, although the selected application site (finger or toe) should be appropriately sized.
This sensor is designed to be used exclusively in Feas electronica equipment.

It has a length of 1 meter.
Protection against liquids: IPX1

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Oximeter sensor, reusable "Y" DB9M/G 3043 Feas Electrónica
Feas Electrónica reusable "Y" oximeter sensor DB9M/G 3043

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Disposable, DB9M/G, Feas ELECTRÓNICA , 520P
Pediatric pulse oximeter sensor DB9M/G

The Oximetry sensor is used for pediatric patient (weighing between 10kg and 50kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electrónica 520N
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electronica 520N

Oximetry sensor is used for neonatal patient (weight < 3kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I

Oximetry sensor is used for infant patient (weighing between 3kg and 20kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H

The Oximetry sensor is used for pediatric patient (weight: 10kg-30kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A

This oximetry sensor is used for adult patients (weighing more than 30 kg) to measure arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
External paddles for 3850B defibrillator
Part of External Paddles for 3850B Desfibrillator Feas Electronica

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pair of Electrodes for pacemaker, Gray color, 95mm diameter
Pair of gray electrodes, 95 mm in diameter, for pacemakers.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermal paper for ECG 50mm x 25m
Brand Sensitherm
Direct Inscription Electrocardiograph Paper. Thermochemical Type.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable electrodes x 10 units
Disposable electrodes x 10 units
For patient cable.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Velcro belt for pacer, 3850B defibrillator
Elastic belt of variable length that allows the support of the electodos to carry out the transcutaneous cardiac stimulation in the thorax of the patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.