Patient Monitor, Multiparameter, of 12,1", Comen, with Batery Li ion include, Touch screen, light, model C80
MULTIPARAMETER MONITOR C80

C80 provides the clinician with advanced functionality and monitoring options to meet the demands of a wide range of care in any hospital setting.
It has a color screen with TFT technology of 10.4" inclined to facilitate observation.
Easy menu use via rotary knob and touch screen.
In addition, it has reserved expansion ports such as for SD card, USB port and network.

Adult, Pediatric, Neonatal Use

ELECTROCARDIOGRAM(ECG)
Heart rate:
•Adult: 15-300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Accuracy: ±1% o ±1 [1/min], whichever is greater.
Resolution: ±1 [1/min]
Gain selection: 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 40mm/mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12 lead ECG input mode.
Selection of leads:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF y V
3. DI, DII, DIII, aVR, aVL, aVF y V1 a V6
Frequency response:
•Monitoring mode: 0.5-40Hz.
•Deagnostic mode: 0.05-130Hz.
•Surgery modality: 1-20Hz.
•ST Mode: 0.05-40hZ.
Heart rate alarms:
•Adult: 15 - 300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ±2mV~±700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia type: PVC, Asystoloe, VTac, Tachycardia, Ventricular tachycardia, Supraventricular tachycardia, VR, Bigeminia, Trigeminia, R on T, Bradycardia, Ventricular bradycardia, missed beats, Atrial fibrillation, Ventricular fibrillation, Non-captured pacemaker (NCP), Non-captured pacemaker (PNP).
ST segment analysis:
Range: -2mV to +2mV
Accuracy: Measurement tolerance within (-0.8 mV)-(+0.8 mV) is ±0.02 mV or ±10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curse, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
Comen SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, the tolerance is ±2% (without movement).
Neonatal Accuracy: within 70% -100%, the tolerance is ±3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE RATE
Comen SpO2:
Range: 20 - 254 [1/min]
Resolution: 1[1/min]
Accuracy: ±2 [1/min]
Alarm: 20 a 350 [1/min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Within 7 [1/min] – 150 [1/min], the measurement error is ±2 rpm or ±2%, whichever is greater.
The tolerance is not defined by other ranges.
Alarm Limit Specification:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscillometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Measurement unit: mmHg
Nominal Monitoring Range:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Alarm Limit Specifications:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric Range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Precision:
The mean error should be less than 5mmHg
The standard deviation should be less than 8mmHg.
Manual or automatic start of measurement at programmable intervals of 1/ 2/ 2.5/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 180/ 240/ 480/ 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
•Adult: When the cuff pressure exceeds 297 mmHg ±3mmHg, the control valve will relieve the pressure.
•Child: When the cuff pressure exceeds 240 mmHg ±3 mmHg, the control valve will relieve the pressure.
•Neonate: When the cuff pressure exceeds 147 mmHg ±3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement Method: direct.
A temperature channel.
Temperature Ranges
Range: 0 - 50° C
Accuracy: ±0.1°C (Exclusive of probe tolerance)
Resolution: 0.1°C
Maximum and minimum temperature alarms:
Range: 0 - 50° C


TECHNICAL SPECIFICATIONS

12.1" color touch screen with TFT technology Resolution: 800 X 600
Inclined screen to facilitate observation.
Dimensions: 344 mm x 291 mm x 165 mm
Weight 3.9 Kg. with battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 – 240 Vac, 50/60 Hz.
C80: Standard: Li-Ion 11.8V/2200mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60VA
Reserved expansion ports such as SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient cable 5 wires for Datascope system 97
PRODUCT DESCRIPTION
5-wire patient cable for Datascope system 97
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / 10 Lead Cable / ECG Cable / EKG Cable

FREQUENT QUESTIONS
What brands is this cable compatible with?
It is compatible with the brand: Mindray with 6-pin circular connector and EDAN M8 LEXX. For other brands or models please consult.

What places do you ship to?
We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient cable DB15M - 10 Wires for Cath labs Feas Electrónica
PRODUCT DESCRIPTION
Patient cable DB15M Feas Electrónica
It has 10 snap buttons.
The length of the cable is 3.9 meters.
Type CF equipment protected against defibrillation.
For Feas Electrónica brand polygraphs.
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / ECG Cable / Electrocardiogram Cable / 10 lead ecg / 10 lead patient cable

What places do you ship to?
We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient cable DB15M - 3 Wires for cath labs
PRODUCT DESCRIPTION
Patient cable DB15M Feas Electrónica
It has 3 snap buttons.
The length of the cable is 3.9 meters.
Type CF equipment protected against defibrillation.
For Feas Electrónica brand polygraphs.
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / ECG Cable / Electrocardiogram Cable / 3 lead ecg / 3 lead patient cable

What places do you ship to?
We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient cable DB15M - 5 Wires for Cath labs Feas Electrónica
PRODUCT DESCRIPTION
Patient cable DB15M Feas Electrónica
It has 5 snap buttons.
The length of the cable is 3.9 meters.
Type CF equipment protected against defibrillation.
For Feas Electrónica brand polygraphs.
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / ECG Cable / Electrocardiogram Cable

What places do you ship to?
We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient line of 2,4 m for sidestream Capnography, Feas Electrónica
Disposable accessory to connect the 'T' type nozzle (which joins the respirator and the patient) to the monitoring system. Its extension is 2,4 meters. The use is exclusive for each patient, in Feas Electronica multiparametric monitor.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pedal for Feas Electrónica equipment with 6,5mm plug, 5m length
Recording pedal for Study Polygraph for Hemodynamics that allows you to start or stop the recording of a study section.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pediatric pulse oximeter with Clamp and DB9M/G, Feas Electrónica 3178
Pediatric pulse oximeter with Clamp and DB9M/G, Feas Electrónica 3178

The reusable finger sensor is used in oximetry monitoring systems to non-invasively determine Oxygen saturation (SpO2), pulse rate, and pulse plethysmographic waves.

The reusable pediatric finger sensor is recommended for:
• Patients weighing more than 5Kg and less than 45Kg.
• Patients with limited activity.
• For sampling.

The reusable pediatric finger sensor is not recommended for long-term use. For long-term patient monitoring, use disposable single-patient or wrap-around type sensors.
It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Physiodispenser micromotor tool hose
Physiodispenser micromotor tool hose
- Months Warranty: 3.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Plastic holder for the micromotor of the Odontology implant system
Plastic holder for the micromotor of the Odontology implant system

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Polycarbonate NIBP parameter, revision 01, front of Multipar LCD version 7.x
Self-adhesive polycarbonate for multipair monitor of the NIBP parameter connector.
Power cord 220 V Schuko type (steck) 4mm CE7/4
Power cable for Feas electronica's equipment with SCHUKO plug and thin pins STECK type.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Power selector switch, wired for Defibrillator 3850B Monophasic
Power selector switch, wired for Defibrillator 3850B Monophasic

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer DTX plusDT-4812 disposable, ref. 682000 version A
Pressure transducer DTX plusDT-4812 disposable

Single Line, 60 Inch Pressure Tubing, Pressure Range -30 to +300 mmHg
Microdrip Chamber, 3 Way Stopcock, Zeroing Stopcock.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer Edwards PX260
Pressure transducer Edwards PX260 that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.

Single TruWave disposable pressure transducer with 3cc flush device and IV set

Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Gold plated connector wires for high fidelity signal transfer

Snap-tab flush device designed for easy priming and square-wave testing

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer adapter cable (DB9/G) to BD transducer
Pressure transducer adapter cable (DB9/G) to BD transducer

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer adapter cable (DB9/G) to BD transducer Edwards
Pressure transducer adapter cable (DB9/G) to BD transducer Edwards

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer adapter cable (DB9/G) to BD transducer Utah
Cable used to adapt the Utah type invasive blood pressure transducer to the patient monitoring system. Exclusive use in a Feas Electrónica multiparameter monitor, under the supervision of trained health care staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer without adaptation B & D DTX plus TNF-R disposable
Pressure transducer without adaptation B & D DTX plus TNF-R disposable
Feas Electronica Patient Monitor Accessory.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.