Oxygen sensor with tongue clips for veterinary use. D9MG, Feas Electrónica. 551A
Oxygen sensor with tongue clips for veterinary use. D9MG, Feas Electronica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Paper compartment door for Comen ECG, model CM300
Paper compartment door for Comen ECG, model CM300

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermoformed, mechanized and milled plastic paddle holder for Defibrillator 3850B
Thermoformed, mechanized and milled plastic paddle holder for 3850B Defibrillator.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Polycarbonate NIBP parameter, revision 01, front of Multipar LCD version 7.x
Self-adhesive polycarbonate for multipair monitor of the NIBP parameter connector.
Self-adhesive polycarbonate of "SILENCE" key for Multipar keyboard
Self-adhesive polycarbonate of "SILENCE" key for Multipar keyboard

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Self-adhesive polycarbonate of key "ESC" for keyboard of Multipar
Self-adhesive polycarbonate of key "ESC" for keyboard of Multipar

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-rechargeable battery Panasonic 3V lithium manganese CR123A (Li-MnO2)
Battery suitable for automated external defibrillators such as Zoll automated external defibrillator
Gray nylon KNOB FOR .250" electronic switch PUSHBUTTON
Grayhill trim knob. Replacement for rotary knob of the Multipair Monitor

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
TID serum hanger
TID serum hanger

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Assembled battery pack Ni-Mh, 12V-4000mAh
Assembled Ni-Mh battery pack, 12V - 4000mAh.
12 months warranty.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, Comen Model C30
The COMEN C30 Multi-Parameter Patient Monitor is the perfect device to meet all your portable monitoring needs in and out of the hospital. In addition, its hardness and quality allow it to withstand a 1.2 meter drop, making it an excellent portable device that meets the needs of all hospitals. Created for use in adult, pediatric and neonatal patients. It can provide users with all the basic monitoring parameters required by their patients.
Strong, stable, waterproof, dustproof, anti-drop and shockproof.
Small and light, easy to carry.
Suitable for emergency scene, out-of-hospital transport, intra-hospital transport, bedside monitoring in the emergency department

Model C-30
Technical specifications
Security
ISO 13485: 2003 Approved
CE marking according to MDD93 / 42 / EEC

Physical characteristics:
Dimensions: 190mmX81.6mmX107mm
weight: 1.2 kg

Operation Environment
Power: 15Vdc
Power supply: 100-250Vac, 50/60 Hz.
Temperature: 0-40 ° C
Humidity: 15-85%
Battery: Lithium-ion, rechargeable
Plug & play battery, capacity: 2600mA
Maximum of 6.5 hours for charging;
4 hours of continuous work

Specifications
Patient: adult, pediatric, neonate
Display: 4.3 "color TFT touch screen
Resolution: 16:9
2 curves on screen
Sweep speed: 12.5mm / s, 25mm / s, 50mm / s
Indicators:
• Battery indicator light
• Dual indicator alarm light
QRS beep and alarm sound
Key sound
AC input socket
MDR
Trend: 48 hours
Alarm: user adjustable high and low limits
Connection to the monitoring center
DVI connection

Breathing
Impedance method
Rate:
• Adult 0-1OOrpm
• Neonatal 0-150 rpm
• Resolution: ± 1 rpm
Apnea alarm: 10s-40s
Audible and visual alarm
Sweep speed: 12.5.25mm/s
Gain selection: x0.25, x0.5, x1, x2

ECG
Cable: 12-lead CardioTecTM,
3 or 5 snaps (selectable)
12 leads: I, Il, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, -V6
5 wire: RA, LA, RL, LL, V or R, L, N, F, C,
3 wire: RA, LA, LL or R, L, F
Lead Selection: 12 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
5 wire: I, Il, IIl, aVR, aVL, aVF, V
3 wire: I, Il, III
Gain selection: x0.25, x0.5, x1, x2, auto
Adult: 15-300 1 / min
Pediatric / neonate: 15-350 1 / min
Accuracy: ± 1% or ± 1 1 / min (whichever is greater)
Resolution: 1 1 / min
ECG bandwidth:
MON: 0.5-55Hz
DIA: 0.05-150 Hz
OPE: 1-20Hz
ST segment detection: ± 2.0mV (automatic)
Arrhythmia Analysis
Pacemaker pulse detection

Temperature
2 channels
Standard sensor: Cutaneous
Measurement range: 0-50 ° C
Resolution: 0.1 ° C
Accuracy: 0.1 ° C (excludes sensor error)
Channel: T1, T2, TD (temperature difference)

PNI
Measurement method: Automatic oscillometric
Working mode: manual / automatic / continuous
Interval: Adjustable from 1 min to 480 min
Measurement types: systolic, diastolic, mean
Unit of measure: mmHg / KPa, adjustable
Systolic pressure range:
• Adult: 40 to 270 mmHg
• Pediatric: 40 to 200mmHg
• Neonate: 40 to 135 mmHg
Diastolic pressure range:
• Adult: 10 to 215 mmHg
• Pediatric: 10 to 150mmHg
• Neonate: 10 to 100 mmHg
Medium pressure range:
• Adult: 20 to 235 mmHg
• Pediatric: 20 to 165mmHg
• Neonate: 20 to 110 mmHg
Overpressure Protection: Hardware and Software
• Accuracy: less than ± 5mmHg
• Resolution: 1mmHg

Sp02 Comen
Range: 1-100%
Resolution: 1%
Accuracy:
• ± 2% (70-100%, Ped, no movement)
• ± 3% (70-100%, Neo, no movement)
• 0-69% unspecified
Range alarm: 0-100%
Pulse Frequency:
• Range: 20 to 300 ppm
• Resolution: 1 ppm
• Accuracy:
- ± 3ppm (no movement)
- ± 5ppm (movement)
Alarm: 20 to 300 ppm

EtCO2
Sidestream CO2 (SideStream)
Range: 0 to 150 mmHg, 0 to 79%,
• 0 to 20 kPa (at 760 mmHg)
• Accuracy: ± 2mm Hg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Response time: <240 ms (10% to 90%)
Delay time: <2s

C02 COMEN Main Flow
Range: 0 to 150 mm Hg, 0 to 79%,
0 to 20 kPa (at 760 mmHg)

Accuracy: ± 2mmHg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Delay time: <2s

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Preventive Maintenance Multipair Monitor
The maintenance procedure will be carried out by trained technical personnel with extensive experience in the technical service of Feas Electrónica equipment.
This service includes:
1- Preventive and corrective maintenance of equipment,
2- Free replacement of defective parts,
3- Software update,
4- Corresponding revisions,
5- Calibration and functional test of all parameters (using calibrated simulators and analyzers),
6- Realization of exit protocols of the equipment
7- Internal and external cleaning of the equipment.

An electrical safety test and calibration certificate will be issued once a year.

It does not include the repair of damages caused by glows, misuse, vandalism, equipment drops, line surges or any loss external to daily use. The provision of equipment accessories is not included, if a provision is required, it will be charged.
Preventive Maintenance Pacemaker
The maintenance procedure will be carried out by trained technical personnel with extensive experience in the technical service of Feas Electrónica equipment.
This service includes:
1- Preventive and corrective maintenance of equipment,
2- The free replacement of defective parts,
3- Software update,
4- Corresponding revisions,
5- Calibration and functional test of all parameters (using calibrated simulators and analyzers),
6- Realization of exit protocols of the equipment
7- Internal and external cleaning of the equipment.

An electrical safety test and calibration certificate will be issued once a year.

It does not include the repair of damages caused by blows, misuse, vandalism, equipment drops, line surges or any loss external to daily use. The provision of equipment accessories is not included, if a provision is required, it will be charged.
Preventive Maintenance Defibrillator
The maintenance procedure will be carried out by trained technical personnel with extensive experience in the technical service of Feas Electrónica equipment.
This service includes:
1- Preventive and corrective maintenance of equipment
2- Free replacement of defective parts
3- Software update
4- Corresponding revisions
5- Calibration and functional test of all parameters (using calibrated simulators and analyzers),
6- Realization of exit protocols of the equipment
7- Internal and external cleaning of the equipment.

An electrical safety test and calibration certificate will be issued once a year.

It does not include the repair of damages caused by blows, misuse, vandalism, equipment drops, line surges or any loss external to daily use. The provision of equipment accessories is not included, if a provision is required, it will be charged.
Handle of pump door, infusion pump Sino MDT Ltd 1500H
Handle of pump door replacement, infusion pump Sino MDT Ltd 1500H.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Transparent silicone hose, internal diameter 3mm, external diameter 4.7mm for TID
Transparent silicone hose, internal diameter 3mm, external diameter 4.7mm for TID

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Physiodispenser micromotor tool hose
Physiodispenser micromotor tool hose
- Months Warranty: 3.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.