Infusion Pump

View Full-Size Image
Multiparameter Patient Monitor


Multiparameter Patient Monitor

Price: Call for Pricing

Ask a question about this product

GENERAL CHARACTERISTICS

FEATURES:

 
  • Menu, messages and instructions
    in English.
  • Single sweep speeds for circulatory
    and respiratory system: 12.5, 25 and
    50 mm/s.
  • Visual and audible QRS indicator proceeding fromECG or Oxymeter.
  • When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
  • Three alarm levels: physiologicals, technicals and generals.
  • Upper and lower limits adjustable by the user.
  • Visual and audible alarm indicators,
    on screen and on top of the equipment.
  • Hotkey to activate the silent alarms for 2 minutes.

 

  • Alarms Turn Off.
  • User friendly menu by using the selector knob and hotkeys.
  • Waveform print-out on standard printer.
  • Analog outputs for ECG, RESP, IBP and a synchronization pulse.
  • Video output for slave or remote monitor (optional).
  • Networking Connection for Centralized Monitoring.
  • WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
  • Screen menu:
    • Normal.
    • 7 leads of ECG.
    • Tabular trends or graphical trends.
    • Frozen and measuring of calipers.
    • Large numbers.

  • BASIC CHANNELS

    ELECTROCARDIOGRAM

    • Heart rate: 20 to 300 [1/min].
    • Gain selection: 1/4, 1/2, 1, 2 and 4 cm/mV, individual or for both channels.
    • Visual and audible QRS indication.
    • Automatic selection of 3 or 5 leads patient cable.
    • 3 leads with 3 leads patient cable. Lead selection: DI, DII or DIII.
    • 12 leads with 5 leads patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and V1, V2, V3, V4, V5 or V6.
    • 50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
    • Heart rate alarms, minimum and maximum: 20 to 300 [1/min] and off.
    • Lead off detection.
    • Pacemaker pulse detection.
    • Pacemaker pulse rejection in counting the heart rate:
      • Pulse rejected characteristic:
        • Amplitude: from ±2 mV to ±700 mV.
        • Pulse width: from 0.1 ms to 2.0 ms.

    ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS

    • Detected and classified the follow arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy, Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
    • Store up to 32 events and allows review and printing.
    • Measurement of the S-T segment: both the isoelectric point and the ST point are user adjustable (J-point +60 ms or +80 ms, or any other value in ms, from 1 to 120 ms).
    • Range: ±2.00 mV.

    RESPIRATORY WAVEFORM

    • Impedancemetric Method
    • Measurement selection: Transabdominal o Transtoraxic.
    • Respiratory rate: 5 to 170 [1/min].
    • Apnea Alarm.
    • Respiratory rate alarm minimum and maximum: 5 to 170 [1/min] and off.

    OXYGEN SATURATION

  • Heart rate: 20 to 300 [1/min].
  • Plethysmographic waveform, Display of percentual oxygen saturation.
  • Measurement signal low perfusion and motion.
  • SpO2:
    • Range: 0% to 100%.
    • Adult precision: 2% from 70% to 100%.
    • Neonate precision: 3% from 70% to 100%.
    • Motion precision: 3% from 70% to 100%.
    • Resolution: 1%.
    • Alarm: 0% to 100% and off.
    • Initial alarm: 85%.
  • Pulse rate:
    • Range: 20 to 300 [1/min].
    • Adult precision: ±3 [1/min].
    • Neonate precision: ±3 [1/min].
    • Motion precision: ±5 [1/min].
    • Resolution: 1 [1/min].
    • Alarm: 20 to 250 [1/min] and off.
  • Waveform gain adjustment x1/2, x1 and x2.
  • NON-INVASIVE BLOOD PRESSURE (NIBP)

    • Oscilometric method.
    • Use: ADULT or NEONATE.
    • Measurement mode: AUTOMATIC or MANUAL.
    • Unit in mmHg.
    • Resolution:
      • Pressure: 1 mmHg.
      • Pulse rate: 1 [1/min].
    • Transductor accuracy: ±3 mmHg.
    • Ranges:
      • ADULT/PEDIATRIC
        • Systolic: 25 to 265 mmHg.
        • Diastolic: 12 to 220 mmHg.
        • Mean: 18 to 245 mmHg.
        • Pulse rate: 40 to 240 [1/min].
      • NEONATE
        •  
          • Systolic: 25 to 135 mmHg.
          • Diastolic: 12 to 110 mmHg.
          • Mean: 18 to 120 mmHg.
          • Pulse rate: 40 to 240 [1/min].
      • Alarm limits of:
        • Systolic pressure from 20 to 255 mmHg and off.
        • Diastolic pressure from 5 to 220 mmHg and off.
      • Display of the last 1440 measurements (48 hours, every 2 minutes).
      • Print-out of the measurements in table form.
      • Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
      • Protections:
        • Double protection from over-pressure.
        • Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
        • Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
        • Protection for exceeding the time of measurement.

    OPTIONAL

    TEMPERATURE

    • Up to 2 channels of temperature.
    • Compatible with Thermistor Series YSI 400.
    • Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
    • Resolution: 0.1ºC. Accuracy: ±0.2ºC.
    • Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

    CARDIAC OUTPUT

    • Input of patient parameters: Weight,Height.
    • Selection of:
      • Injectate volume: 3, 5 and 10 ml.
      • Catheter Constant K or Computing Constant (CC).
      • Measurement of temperature in blood and injected.
    • Calculation of:
      • Body surface.
      • CO: Volume in litres/min.
      • SV: Systolic volume.
      • CI: Cardiac index.
      • SI: Systolic index.
    • Waveform graph for blood temperature as a function of time.
    • Manual or automatic start of the measurement, at perform the injection.

    INVASIVE BLOOD PRESSURE (IBP)

    • Up to 2 channels of invasive blood pressure.
    • Simultaneous measurement of
      Systolic, Diastolic and Mean
      pressure.
    • Range: -30 to 300 mmHg.
    • Mode selection for Pressure Ranges: Automatic or Manual.
    • Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
    • Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
    • Units in mmHg.
    • CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

    FiO2

    • Fraction of inspired Oxygen: from 0% to 100%.
    • Polarographic cell measurement principle.
    • Alarms minimum and maximum: 0% to 100% and off.

    EEG

    • Two EEG channels.

    RECORDER

    • Direct access key for record
      command.
    • High resolution thermal array printer.
    • Recorder speed: 25 mm/s.
    • Recorded in real time up to 2
      selectable waveforms between ECG,
      RESP, IBP, SpO2 and CO2
      waveform.
    • Prints the table of cardiac output
      measurement and the waveform of
      blood temperature, during the injected.
    • Prints the header with date and time.
    • Print values of Sweep Speed, Lead,
      Gain, Respiratory Rate, Heart Rate,
      Systolic, Diastolic and Mean
      Pressure, SpO2 and Pulse Rate,
      EtCO2, FiCO2 and Respiratory Rate
      (CO2), according recorded waveform.

    CAPNOGRAPHY

    Option 1: Sidestream
    • Measurement of EtCO2, FiCO2 and Respiratory Rate.
    • Range:
      • CO2, from 0 to 100 mmHg (0% to 13%).
      • Respiratory Rate: 4 to 170 [1/min].
    • Accuracy:
      • CO2, ±2 mmHg for CO2<5%.
      • <10% of reading for CO2>5%.
    • Resolution:
      • CO2, 1mmHg.
      • Respiratory Rate, 1 [1/min].
    • Alarm:
      • FiCO2, EtCO2 minimum and maximum, 0 to 100mmHg and off.
      • Respiratory Rate minimum and maximum, 0 to 170 [1/min] and off.
    • Two calibration points: zero (room air) and gains (5% or 10%).
    • Compensation for temperature and atmospheric pressure, O2 y N2O.

    Option 2: Sidestream with anesthetic gases measurement
    • Measurement of EtCO2, FiCO2 and Respiratory Rate.
    • Range:
      • CO2, from 0 to 100 mmHg (0% to 13%).
      • Respiratory Rate, 4 to 150 [1/min].
    • Accuracy:
      • CO2, ±3%ABS.
    • Resolution:
      • CO2, 1 mmHg.
      • Respiratory Rate, 1 [1/min].
    • Alarm:
      • FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
      • Respiratory Rate minimum and maximum, 0 to 150 [1/min] and off.
    • Measurement of expired and inspired O2: from 0% to 100%, Resolution: 1%.
    • Measurement of N2 O: from 0% to 100%.
    • Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane, Isoflurane, Sevoflurane and Desflurane.
      • Range: 0% to 30%.
      • Accuracy: ±8%REL.
      • Resolution: 0.1%.
    • Flowrate:
      • 70 to 120 ml/min for neonatal patients.
      • 120 to 250 ml/min for adult patients.

    Option 3: Mainstream
    • Measurement of EtCO2, FiCO2 and Respiratory Rate.
    • Range:
      • CO2, from 0 to 100 mmHg (0% to 13%).
      • Respiratory Rate, 4 to 150 [1/min].
    • Accuracy:
      • ±2 mmHg from 0 to 40 mmHg.
      • ±5% of reading from 41 to 70 mmHg.
    • Resolution: 1 mmHg.
    • Calibration: only zero (room air).
    • Compensation for temperature and atmospheric pressure, O2 y N2O.
    • Warm-up time <15s, to start measuring, within 2 minutes to obtain values consistent with the specifications.
    • Waveform response time: less than 60ms.

    BATTERY

    • 14.4V / 8.8Ah Li-ion battery.
    • Autonomy: 3.5 hours.
    • Battery state indication (empty, full, on charge) on screen.

    Any other optional channel specified can be added in the future.

    ACCESORIES

    TECHNICAL SPECIFICATIONS

    Included:
    • 3 or 5 leads patient cable.
    • Disposable electrodes.
    • SpO2 sensor.
    • SpO2 Extension cable.
    • Power cord.
    • User manual.
    • Optional accessories for channels that have been acquired.
    • 15” LCD-TFT Color Monitor:
      • Resolution: 1024x768.
      • Greater angle of view.
    • Dimensions:
      • Height: 345mm; Width: 335mm; Depth: 205mm.
      • Weight: 6Kg.
    • Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
    • Power Consumption: 60VA.
    • Quality Standard: ISO 9001, ISO 13485, Disp. A.N.M.A.T. 3266/2013: B.P.F. and Disp. A.N.M.A.T. 2319/02, certified.
    • Safety Standard: UNE-EN60601-1.(Eq. IRAM 4220-1 and IEC 601-1) Electrical-shock protection: Class I - CF, UNE-EN60601-1-2 (Electromagnetic compatibility), certified.
    • Authorized by A.N.M.A.T.: PM-1125-2.

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
    USAGE ENVIRONMENTS:
    Ambulances, Intensive Care Units, Coronary Units, Operation Theaters

    multiparameter monitor.pdf